The vast majority of the CVs implemented in PLUMED are calculated from a list of atom positions. Within PLUMED atoms are specified using their numerical indices in the molecular dynamics input file.
In PLUMED lists of atoms can be either provided directly inside the definition of each collective variable, or predefined as a GROUP that can be reused multiple times. Lists of atoms can be written as:
GROUP ATOMS=10,11,15,20 LABEL=g1
)GROUP ATOMS=10-20 LABEL=g2
is equivalent to GROUP ATOMS=10,11,12,13,14,15,16,17,18,19,20 LABEL=g2
GROUP ATOMS=10-100:10 LABEL=g3 is equivalent to
GROUP ATOMS=10,20,30,40,50,60,70,80,90,100 LABEL=g3
atoms ranges with a negative stride. So
GROUP ATOMS=100-10:-10 LABEL=g4 is equivalent to GROUP ATOMS=100,90,80,70,60,50,40,30,20,10 LABEL=g4
In addition, there are a few shortcuts that can be used:
@mdatoms
indicate all the physical atoms present in the MD engine (e.g. DUMPATOMS ATOMS=@mdatoms
).@allatoms
indicates all atoms, including those defined only in PLUMED (e.g. DUMPATOMS ATOMS=@allatoms
).The list of the virtual atoms defined in PLUMED can be obtained by using the command GROUP ATOMS=@allatoms REMOVE=@mdatoms
.
Other shortcuts are available if you loaded the structure of the molecule using the MOLINFO command.
All the above methods can be combined just putting one name after the other separated by a comma:
g5: DUMPATOMSATOMS=1,2,10-20,40-60:5,100-70:-2the atom indices whose positions you would like to print out.FILE=test.xyzcompulsory keyword file on which to output coordinates; extension is automatically detected
Some collective variable must accept a fixed number of atoms, for example a DISTANCE is calculated using two atoms only, an ANGLE is calculated using either 3 or 4 atoms and TORSION is calculated using 4 atoms.
Additional material and examples can be also found in the tutorial Belfast tutorial: Analyzing CVs.
In addition, for certain colvars, pdb files can be read in using the following keywords and used to select ATOMS:
MOLINFO | This command is used to provide information on the molecules that are present in your system. |
PLUMED is designed so that for the majority of the CVs implemented the periodic boundary conditions are treated in the same manner as they would be treated in the host code. In some codes this can be problematic when the colvars you are using involve some property of a molecule. These codes allow the atoms in the molecules to become separated by periodic boundaries, a fact which PLUMED could only deal with were the topology passed from the MD code to PLUMED. Making this work would involve a lot laborious programming and goes against our original aim of having a general patch that can be implemented in a wide variety of MD codes. Consequentially, we have implemented a more pragmatic solution to this problem - the user specifies in input any molecules (or parts of molecules) that must be kept in tact throughout the simulation run. In PLUMED 1 this was done using the ALIGN_ATOMS keyword. In PLUMED 2 the same effect can be achieved using the WHOLEMOLECULES command.
The following input computes the end-to-end distance for a polymer of 100 atoms and keeps it at a value around 5.
WHOLEMOLECULESENTITY0=1-100 e2e: DISTANCEthe atoms that make up a molecule that you wish to align.ATOMS=1,100the pair of atom that we are calculating the distance between.NOPBCRESTRAINT( default=off ) ignore the periodic boundary conditions when calculating distancesARG=e2ethe input for this action is the scalar output from one or more other actions.KAPPA=1compulsory keyword ( default=0.0 ) specifies that the restraint is harmonic and what the values of the force constants on each of the variables areAT=5compulsory keyword the position of the restraint
Notice that NOPBC is used to be sure in DISTANCE that if the end-to-end distance is larger than half the simulation box the distance is compute properly. Also notice that, since many MD codes break molecules across cell boundary, it might be necessary to use the WHOLEMOLECULES keyword (also notice that it should be before distance).
Notice that most expressions are invariant with respect to a change in the order of the atoms, but some of them depend on that order. E.g., with WHOLEMOLECULES it could be useful to specify atom lists in a reversed order.
# to see the effect, one could dump the atoms as they were before molecule reconstruction: # DUMPATOMS FILE=dump-broken.xyz ATOMS=1-20 WHOLEMOLECULESSTRIDE=1compulsory keyword ( default=1 ) the frequency with which molecules are reassembled.ENTITY0=1-20 DUMPATOMSthe atoms that make up a molecule that you wish to align.FILE=dump.xyzcompulsory keyword file on which to output coordinates; extension is automatically detectedATOMS=1-20the atom indices whose positions you would like to print out.
Notice that there are other ways to manipulate the coordinates stored within PLUMED:
Sometimes, when calculating a colvar, you may not want to use the positions of a number of atoms directly. Instead you may wish to use the position of a virtual atom whose position is generated based on the positions of a collection of other atoms. For example you might want to use the center of mass of a group of atoms. Plumed has a number of routines for calculating the positions of these virtual atoms from lists of atoms:
CENTER | Calculate the center for a group of atoms, with arbitrary weights. |
CENTER_OF_MULTICOLVAR | Calculate a a weighted average position based on the value of some multicolvar. |
COM | Calculate the center of mass for a group of atoms. |
FIXEDATOM | Add a virtual atom in a fixed position. |
GHOST | Calculate the absolute position of a ghost atom with fixed coordinates in the local reference frame formed by three atoms. |
To specify to a colvar that you want to use the position of a virtual atom to calculate a colvar rather than one of the atoms in your system you simply use the label for your virtual atom in place of the usual numerical index. Virtual atoms and normal atoms can be mixed together in the input to colvars as shown below:
com1: COMATOMS=1,10 DISTANCEthe list of atoms which are involved the virtual atom's definition.ATOMS=11,com1the pair of atom that we are calculating the distance between.
If you don't want to calculate CVs from the virtual atom. That is to say you just want to monitor the position of a virtual atom (or any set of atoms) over the course of your trajectory you can do this using DUMPATOMS.