This is part of the isdb module |
Calculates the Pseudo-contact shift of a nucleus determined by the presence of a metal ion susceptible to anisotropic magnetization.
The PCS of an atomic nucleus depends on the \(\theta\) angle between the vector from the spin-label to the nucleus and the external magnetic field and the module of the vector itself [28] . While in principle the averaging resulting from the tumbling should remove the pseudo-contact shift, in presence of the NMR magnetic field the magnetically anisotropic molecule bound to system will break the rotational symmetry does resulting in measurable values for the PCS and RDC.
PCS values can also be calculated using a Single Value Decomposition approach, in this case the code rely on the a set of function from the GNU Scientific Library (GSL). (With SVD forces are not currently implemented).
Replica-Averaged simulations can be performed using PCS values, ENSEMBLE, STATS and RESTRAINT . Metainference simulations can be performed with this CV and METAINFERENCE .
The names of the components in this action can be customized by the user in the actions input file. However, in addition to the components that can be customized the following quantities will always be output
Quantity | Description |
sigma | uncertainty parameter |
sigmaMean | uncertainty in the mean estimate |
acceptSigma | MC acceptance |
rdc | the calculated # RDC |
In addition the following quantities can be calculated by employing the keywords listed below
Quantity | Keyword | Description |
acceptScale | SCALEDATA | MC acceptance |
weight | REWEIGHT | weights of the weighted average |
biasDer | REWEIGHT | derivatives with respect to the bias |
scale | SCALEDATA | scale parameter |
offset | ADDOFFSET | offset parameter |
ftilde | GENERIC | ensemble average estimator |
exp | SVD/ADDCOUPLINGS | the experimental # RDC |
ATOMS | the couple of atoms involved in each of the bonds for which you wish to calculate the RDC. Keywords like ATOMS1, ATOMS2, ATOMS3,... should be listed and one dipolar coupling will be calculated for each ATOMS keyword you specify. You can use multiple instances of this keyword i.e. ATOMS1, ATOMS2, ATOMS3... |
NOISETYPE | ( default=MGAUSS ) functional form of the noise (GAUSS,MGAUSS,OUTLIERS,MOUTLIERS,GENERIC) |
LIKELIHOOD | ( default=GAUSS ) the likelihood for the GENERIC metainference model, GAUSS or LOGN |
DFTILDE | ( default=0.1 ) fraction of sigma_mean used to evolve ftilde |
SCALE0 | ( default=1.0 ) initial value of the scaling factor |
SCALE_PRIOR | ( default=FLAT ) either FLAT or GAUSSIAN |
OFFSET0 | ( default=0.0 ) initial value of the offset |
OFFSET_PRIOR | ( default=FLAT ) either FLAT or GAUSSIAN |
SIGMA0 | ( default=1.0 ) initial value of the uncertainty parameter |
SIGMA_MIN | ( default=0.0 ) minimum value of the uncertainty parameter |
SIGMA_MAX | ( default=10. ) maximum value of the uncertainty parameter |
OPTSIGMAMEAN | ( default=NONE ) Set to NONE/SEM to manually set sigma mean, or to estimate it on the fly |
WRITE_STRIDE | ( default=10000 ) write the status to a file every N steps, this can be used for restart/continuation |
GYROM | ( default=1. ) Add the product of the gyromagnetic constants for the bond. |
SCALE | ( default=1. ) Add the scaling factor to take into account concentration and other effects. |
NUMERICAL_DERIVATIVES | ( default=off ) calculate the derivatives for these quantities numerically |
DOSCORE | ( default=off ) activate metainference |
NOENSEMBLE | ( default=off ) don't perform any replica-averaging |
REWEIGHT | ( default=off ) simple REWEIGHT using the ARG as energy |
SCALEDATA | ( default=off ) Set to TRUE if you want to sample a scaling factor common to all values and replicas |
ADDOFFSET | ( default=off ) Set to TRUE if you want to sample an offset common to all values and replicas |
NOPBC | ( default=off ) ignore the periodic boundary conditions when calculating distances |
SVD | ( default=off ) Set to TRUE if you want to back calculate using Single Value Decomposition (need GSL at compilation time). |
ADDCOUPLINGS | ( default=off ) Set to TRUE if you want to have fixed components with the experimental values. |
ARG | the input for this action is the scalar output from one or more other actions. The particular scalars that you will use are referenced using the label of the action. If the label appears on its own then it is assumed that the Action calculates a single scalar value. The value of this scalar is thus used as the input to this new action. If * or *.* appears the scalars calculated by all the proceeding actions in the input file are taken. Some actions have multi-component outputs and each component of the output has a specific label. For example a DISTANCE action labelled dist may have three components x, y and z. To take just the x component you should use dist.x, if you wish to take all three components then use dist.*.More information on the referencing of Actions can be found in the section of the manual on the PLUMED Getting Started. Scalar values can also be referenced using POSIX regular expressions as detailed in the section on Regular Expressions. To use this feature you you must compile PLUMED with the appropriate flag. You can use multiple instances of this keyword i.e. ARG1, ARG2, ARG3... |
AVERAGING | Stride for calculation of averaged weights and sigma_mean |
SCALE_MIN | minimum value of the scaling factor |
SCALE_MAX | maximum value of the scaling factor |
DSCALE | maximum MC move of the scaling factor |
OFFSET_MIN | minimum value of the offset |
OFFSET_MAX | maximum value of the offset |
DOFFSET | maximum MC move of the offset |
REGRES_ZERO | stride for regression with zero offset |
DSIGMA | maximum MC move of the uncertainty parameter |
SIGMA_MEAN0 | starting value for the uncertainty in the mean estimate |
TEMP | the system temperature - this is only needed if code doesn't pass the temperature to plumed |
MC_STEPS | number of MC steps |
MC_STRIDE | MC stride |
MC_CHUNKSIZE | MC chunksize |
STATUS_FILE | write a file with all the data useful for restart/continuation of Metainference |
SELECTOR | name of selector |
NSELECT | range of values for selector [0, N-1] |
RESTART | allows per-action setting of restart (YES/NO/AUTO) |
COUPLING | Add an experimental value for each coupling (needed by SVD and useful for STATS). You can use multiple instances of this keyword i.e. COUPLING1, COUPLING2, COUPLING3... |
In the following example five PCS values are defined and their correlation with respect to a set of experimental data is calculated and restrained. In addition, and only for analysis purposes, the same PCS values are calculated using a Single Value Decomposition algorithm.
PCS ... ATOMS1=20,21 ATOMS2=20,38 ATOMS3=20,57 ATOMS4=20,77 ATOMS5=20,93 LABEL=nh ... PCS enh: ENSEMBLE ARG=nh.* st: STATS ARG=enh.* PARAMETERS=8.17,-8.271,-10.489,-9.871,-9.152 pcse: RESTRAINT ARG=st.corr KAPPA=0. SLOPE=-25000.0 AT=1. PRINT ARG=st.corr,pcse.bias FILE=colvar