This is part of the ves module | |
It is only available if you configure PLUMED with ./configure –enable-modules=ves . Furthermore, this feature is still being developed so take care when using it and report any problems on the mailing list. |
Implementation of VES \(\Delta F\) method [67] (step two only).
First you should create some estimate of the local free energy basins of your system, using e.g. multiple METAD short runs, and combining them with the sum_hills utility. Once you have them, you can use this bias Action to perform the VES optimization part of the method.
These \(N+1\) local basins are used to model the global free energy. In particular, given the conditional probabilities \(P(\mathbf{s}|i)\propto e^{-\beta F_i(\mathbf{s})}\) and the probabilities of being in a given basin \(P_i\), we can write:
\[ e^{-\beta F(\mathbf{s})}\propto P(\mathbf{s})=\sum_{i=0}^N P(\mathbf{s}|i)P_i \, . \]
We use this free energy model and the chosen bias factor \(\gamma\) to build the bias potential: \(V(\mathbf{s})=-(1-1/\gamma)F(\mathbf{s})\). Or, more explicitly:
\[ V(\mathbf{s})=(1-1/\gamma)\frac{1}{\beta}\log\left[e^{-\beta F_0(\mathbf{s})} +\sum_{i=1}^{N} e^{-\beta F_i(\mathbf{s})} e^{-\beta \alpha_i}\right] \, , \]
where the parameters \(\boldsymbol{\alpha}\) are the \(N\) free energy differences (see below) from the \(F_0\) basin.
By default the \(F_i(\mathbf{s})\) are shifted so that \(\min[F_i(\mathbf{s})]=0\) for all \(i=\{0,...,N\}\). In this case the optimization parameters \(\alpha_i\) are the difference in height between the minima of the basins. Using the keyword NORMALIZE
, you can also decide to normalize the local free energies so that \(\int d\mathbf{s}\, e^{-\beta F_i(\mathbf{s})}=1\). In this case the parameters will represent not the difference in height (which depends on the chosen CVs), but the actual free energy difference, \(\alpha_i=\Delta F_i\).
However, as discussed in Ref. [67], a better estimate of \(\Delta F_i\) should be obtained through the reweighting procedure.
The following performs the optimization of the free energy difference between two metastable basins:
cv: DISTANCEATOMS=1,2 ves: VES_DELTA_F ...the pair of atom that we are calculating the distance between.ARG=cvthe input for this action is the scalar output from one or more other actions.TEMP=300temperature is compulsory, but it can be sometimes fetched from the MD engineFILE_F0=fesA.datacompulsory keyword names of files containing local free energies and derivatives.FILE_F1=fesB.datacompulsory keyword names of files containing local free energies and derivatives.BIASFACTOR=10.0compulsory keyword ( default=0 ) the \f$\gamma\f$ bias factor used for well-tempered target \f$p(\mathbfs)\f$.M_STEP=0.1compulsory keyword ( default=1.0 ) the \f$\mu\f$ step used for the \f$\Omega\f$ functional minimizationAV_STRIDE=500compulsory keyword ( default=500 ) number of simulation steps between alpha updatesPRINT_STRIDE=100 ... PRINT( default=10 ) stride for printing to ALPHA_FILEFMT=%gthe format that should be used to output real numbersSTRIDE=500compulsory keyword ( default=1 ) the frequency with which the quantities of interest should be outputFILE=Colvar.datathe name of the file on which to output these quantitiesARG=cv,ves.bias,ves.rctthe input for this action is the scalar output from one or more other actions.
The local FES files can be obtained as described in Sec. 4.2 of Ref. [67], i.e. for example:
cat HILLS* > all_HILLS
plumed sum_hills --hills all_HILLS --outfile all_fesA.dat --mintozero --min 0 --max 1 --bin 100
awk -v n_rep=4 '{if($1!="#!" && $1!="") {for(i=1+(NF-1)/2; i<=NF; i++) $i/=n_rep;} print $0}' all_fesA.dat > fesA.data
The header of both FES files must be identical, and should be similar to the following:
#! FIELDS cv file.free der_cv #! SET min_cv 0 #! SET max_cv 1 #! SET nbins_cv 100 #! SET periodic_cv false 0 0 0
#! FIELDS cv file.free der_cv #! SET min_cv 0 #! SET max_cv 1 #! SET nbins_cv 100 #! SET periodic_cv false 0 0 0
By default this Action calculates the following quantities. These quantities can be referenced elsewhere in the input by using this Action's label followed by a dot and the name of the quantity required from the list below.
Quantity | Description |
bias | the instantaneous value of the bias potential |
rct | the reweighting factor \(c(t)\) |
work | the work done by the bias in one AV_STRIDE |
FILE_F | names of files containing local free energies and derivatives. The first one, FILE_F0, is used as reference for all the free energy differences. You can use multiple instances of this keyword i.e. FILE_F1, FILE_F2, FILE_F3... |
BIASFACTOR | ( default=0 ) the \(\gamma\) bias factor used for well-tempered target \(p(\mathbf{s})\). Set to 0 for non-tempered flat target |
M_STEP | ( default=1.0 ) the \(\mu\) step used for the \(\Omega\) functional minimization |
AV_STRIDE | ( default=500 ) number of simulation steps between alpha updates |
ALPHA_FILE | ( default=ALPHA ) file name for output minimization parameters |
NUMERICAL_DERIVATIVES | ( default=off ) calculate the derivatives for these quantities numerically |
NORMALIZE | ( default=off ) normalize all local free energies so that alpha will be (approx) \(\Delta F\) |
NO_MINTOZERO | ( default=off ) leave local free energies as provided, without shifting them to zero min |
DAMPING_OFF | ( default=off ) do not use an AdaGrad-like term to rescale M_STEP |
SERIAL | ( default=off ) perform the calculation in serial even if multiple tasks are available |
MULTIPLE_WALKERS | ( default=off ) use multiple walkers connected via MPI for the optimization |
ARG | the input for this action is the scalar output from one or more other actions. The particular scalars that you will use are referenced using the label of the action. If the label appears on its own then it is assumed that the Action calculates a single scalar value. The value of this scalar is thus used as the input to this new action. If * or *.* appears the scalars calculated by all the proceeding actions in the input file are taken. Some actions have multi-component outputs and each component of the output has a specific label. For example a DISTANCE action labelled dist may have three components x, y and z. To take just the x component you should use dist.x, if you wish to take all three components then use dist.*.More information on the referencing of Actions can be found in the section of the manual on the PLUMED Getting Started. Scalar values can also be referenced using POSIX regular expressions as detailed in the section on Regular Expressions. To use this feature you you must compile PLUMED with the appropriate flag. You can use multiple instances of this keyword i.e. ARG1, ARG2, ARG3... |
TEMP | temperature is compulsory, but it can be sometimes fetched from the MD engine |
TG_STRIDE | ( default=1 ) number of AV_STRIDE between updates of target \(p(\mathbf{s})\) and reweighing factor \(c(t)\) |
TAU_MEAN | exponentially decaying average for alpha (rescaled using AV_STRIDE). Should be used only in very specific cases |
INITIAL_ALPHA | ( default=0 ) an initial guess for the bias potential parameter alpha |
PRINT_STRIDE | ( default=10 ) stride for printing to ALPHA_FILE |
FMT | specify format for ALPHA_FILE |
RESTART | allows per-action setting of restart (YES/NO/AUTO) |