This is part of the colvar module |
This Colvar calculates path collective variables.
This is the Path Collective Variables implementation ( see [23] ). This variable computes the progress along a given set of frames that is provided in input ("sss" component) and the distance from them ("zzz" component). (see below).
When running with periodic boundary conditions, the atoms should be in the proper periodic image. This is done automatically since PLUMED 2.5, by considering the ordered list of atoms and rebuilding molecules with a procedure that is equivalent to that done in WHOLEMOLECULES . Notice that rebuilding is local to this action. This is different from WHOLEMOLECULES which actually modifies the coordinates stored in PLUMED.
In case you want to recover the old behavior you should use the NOPBC flag. In that case you need to take care that atoms are in the correct periodic image.
Here below is a case where you have defined three frames and you want to calculate the progress along the path and the distance from it in p1
p1: PATHMSDREFERENCE=file.pdbcompulsory keyword the pdb is needed to provide the various milestonesLAMBDA=500.0compulsory keyword the lambda parameter is needed for smoothing, is in the units of plumedNEIGH_STRIDE=4how often the neighbor list needs to be calculated in time unitsNEIGH_SIZE=8 PRINTsize of the neighbor listARG=p1.sss,p1.zzzthe input for this action is the scalar output from one or more other actions.STRIDE=1compulsory keyword ( default=1 ) the frequency with which the quantities of interest should be outputFILE=colvarthe name of the file on which to output these quantitiesFMT=%8.4fthe format that should be used to output real numbers
note that NEIGH_STRIDE=4 NEIGH_SIZE=8 control the neighbor list parameter (optional but recommended for performance) and states that the neighbor list will be calculated every 4 steps and consider only the closest 8 member to the actual md snapshots.
This input must be accompanied by a REFERENCE PDB file in which the positions of each of the frames are specified separated using either END or ENDMDL as shown below:
ATOM 1 CL ALA 1 -3.171 0.295 2.045 1.00 1.00 ATOM 5 CLP ALA 1 -1.819 -0.143 1.679 1.00 1.00 ATOM 6 OL ALA 1 -1.177 -0.889 2.401 1.00 1.00 ATOM 7 NL ALA 1 -1.313 0.341 0.529 1.00 1.00 END ATOM 1 CL ALA 1 -3.175 0.365 2.024 1.00 1.00 ATOM 5 CLP ALA 1 -1.814 -0.106 1.685 1.00 1.00 ATOM 6 OL ALA 1 -1.201 -0.849 2.425 1.00 1.00 ATOM 7 NL ALA 1 -1.296 0.337 0.534 1.00 1.00 END ATOM 1 CL ALA 1 -2.990 0.383 2.277 1.00 1.00 ATOM 5 CLP ALA 1 -1.664 -0.085 1.831 1.00 1.00 ATOM 6 OL ALA 1 -0.987 -0.835 2.533 1.00 1.00 ATOM 7 NL ALA 1 -1.227 0.364 0.646 1.00 1.00 END
By default this Action calculates the following quantities. These quantities can be referenced elsewhere in the input by using this Action's label followed by a dot and the name of the quantity required from the list below.
Quantity | Description |
sss | the position on the path |
zzz | the distance from the path |
LAMBDA | the lambda parameter is needed for smoothing, is in the units of plumed |
REFERENCE | the pdb is needed to provide the various milestones |
NUMERICAL_DERIVATIVES | ( default=off ) calculate the derivatives for these quantities numerically |
NOPBC | ( default=off ) ignore the periodic boundary conditions when calculating distances |
NEIGH_SIZE | size of the neighbor list |
NEIGH_STRIDE | how often the neighbor list needs to be calculated in time units |
EPSILON | (default=-1) the maximum distance between the close and the current structure, the positive value turn on the close structure method |
LOG_CLOSE | (default=0) value 1 enables logging regarding the close structure |
DEBUG_CLOSE | (default=0) value 1 enables extensive debugging info regarding the close structure, the simulation will run much slower |