Defines a wall for the value of one or more collective variables, which limits the region of the phase space accessible during the simulation.
The restraining potential starts acting on the system when the value of the CV is greater (in the case of UPPER_WALLS) or lower (in the case of LOWER_WALLS) than a certain limit \(a_i\) (AT) minus an offset \(o_i\) (OFFSET). The expression for the bias due to the wall is given by:
for UPPER_WALLS: \( \sum_i {k_i}((x_i-a_i+o_i)/s_i)^e_i \)
for LOWER_WALLS: \( \sum_i {k_i}|(x_i-a_i-o_i)/s_i|^e_i \)
\(k_i\) (KAPPA) is an energy constant in internal unit of the code, \(s_i\) (EPS) a rescaling factor and \(e_i\) (EXP) the exponent determining the power law. By default: EXP = 2, EPS = 1.0, OFFSET = 0.
Examples
The following input tells plumed to add both a lower and an upper walls on the distance between atoms 3 and 5 and the distance between atoms 2 and 4. The lower and upper limits are defined at different values. The strength of the walls is the same for the four cases. It also tells plumed to print the energy of the walls.
Click on the labels of the actions for more information on what each action computes
the pair of atom that we are calculating the distance between.
=3,5 The DISTANCE action with label d1 calculates a single scalar valued2: DISTANCE
ATOMS
the pair of atom that we are calculating the distance between.
=2,4 The DISTANCE action with label d2 calculates a single scalar valuePRINT
ARG
compulsory keyword
the labels of the values that you would like to print to the file
=uwall.bias,lwall.bias The PRINT action with label
Glossary of keywords and components
Description of components
By default this Action calculates the following quantities. These quantities can be referenced elsewhere in the input by using this Action's label followed by a dot and the name of the quantity required from the list below.
Quantity
Description
bias
the instantaneous value of the bias potential
force2
the instantaneous value of the squared force due to this bias potential
Compulsory keywords
AT
the positions of the wall. The a_i in the expression for a wall.
KAPPA
the force constant for the wall. The k_i in the expression for a wall.
OFFSET
( default=0.0 ) the offset for the start of the wall. The o_i in the expression for a wall.
EXP
( default=2.0 ) the powers for the walls. The e_i in the expression for a wall.
EPS
( default=1.0 ) the values for s_i in the expression for a wall
Options
ARG
the arguments on which the bias is acting. You can use multiple instances of this keyword i.e. ARG1, ARG2, ARG3...