BF_COSINE
This is part of the ves module
It is only available if you configure PLUMED with ./configure –enable-modules=ves . Furthermore, this feature is still being developed so take care when using it and report any problems on the mailing list.

Fourier cosine basis functions.

Use as basis functions Fourier cosine series defined on a periodic interval. You need to provide the periodic interval \([a,b]\) on which the basis functions are to be used, and the order of the expansion \(N\) (i.e. the highest Fourier cosine mode used). The total number of basis functions is \(N+1\) as the constant \(f_{0}(x)=1\) is also included. These basis functions should only be used for periodic CVs. They can be useful if the periodic function being expanded is an even function, i.e. \(F(-x)=F(x)\).

The Fourier cosine basis functions are given by

\begin{align} f_{0}(x) &= 1 \\ f_{1}(x) &= cos(\frac{2\pi }{P} x) \\ f_{2}(x) &= cos(2 \cdot \frac{2\pi}{P} x) \\ f_{3}(x) &= cos(3 \cdot \frac{2\pi}{P} x) \\ & \vdots \\ f_{n}(x) &= cos(n \cdot \frac{2\pi}{P} x) \\ & \vdots \\ f_{N}(x) &= cos(N \cdot \frac{2\pi}{P} x) \\ \end{align}

where \(P=(b-a)\) is the periodicity of the interval. They are orthogonal over the interval \([a,b]\)

\[ \int_{a}^{b} dx \, f_{n}(x)\, f_{m}(x) = \begin{cases} 0 & n \neq m \\ (b-a) & n = m = 0 \\ (b-a)/2 & n = m \neq 0 \end{cases}. \]

Examples

Here we employ a Fourier cosine expansion of order 10 over the periodic interval \(-\pi\) to \(+\pi\). This results in a total number of 11 basis functions. The label used to identify the basis function action can then be referenced later on in the input file.

Click on the labels of the actions for more information on what each action computes
tested on master
bf1: BF_COSINE 
MINIMUM
compulsory keyword The minimum of the interval on which the basis functions are defined.
=-pi
MAXIMUM
compulsory keyword The maximum of the interval on which the basis functions are defined.
=+pi
ORDER
compulsory keyword The order of the basis function expansion.
=10
Glossary of keywords and components
Compulsory keywords
ORDER The order of the basis function expansion.
MINIMUM The minimum of the interval on which the basis functions are defined.
MAXIMUM The maximum of the interval on which the basis functions are defined.
Options
DEBUG_INFO ( default=off ) Print out more detailed information about the basis set. Useful for debugging.
NUMERICAL_INTEGRALS

( default=off ) Calculate basis function integral for the uniform distribution numerically. Useful for debugging.